Abstract. The article focuses on the clinical applications of temporary crowns manufactured using CAD/CAM technology for the long-term protection of teeth with vital pulp. The authors present a clinical case of patient N, who underwent reconstructive dental prosthetics with crowns designed and manufactured using a digital protocol.
Study purpose. Evaluation of the clinical effectiveness of using temporary crowns made by 3D modeling and milling on prepared vital teeth.
Materials and methods. Clinical observation for one month on the condition of the condition of six vital maxillary teeth prepared for all-ceramic crowns with immediate coverage by milled provisional crowns. Radiovisiography, 3D tomography, and electroodontodiagnostics were used for the initial and repeated examination. Radiovisiography, 3D tomography, and electroodontodiagnostics were used for the initial and repeated examination of the teeth. Intraoral scanning and Exocad software were utilized to assess occlusal relationships, plan, and design prosthetic devices. Provisional crowns were fabricated using 3D milling (Mill Box software (CIM system), DG shape milling machine (Roland) and fixed with RelyX Temp NE (3M ESPE) temporary cement.
Results. During the observation period, all teeth showed normal pulp electrical excitability, no clinical or radiological changes in the periodontium, and no complaints of discomfort in the prepared teeth or unsatisfactory fixation of the prosthetic structures.
Conclusions. Temporary crowns made using the CAD/CAM system by milling can be recommended for the restoration of teeth with vital pulp.

Downloads

Download data is not yet available.

Author Biographies

V. Skibitsky, Bogomolets National Medical University, Kyiv, Ukraine

Candidate of Medical Sciences, Associate Professor of the Department of Orthopedic Dentistry

H. Zakharova, Bogomolets National Medical University, Kyiv, Ukraine

Candidate of Medical Sciences, Associate Professor of the Department of Orthopedic Dentistry

References

Serhii M Hermanchuk, Volodymyr I Struk, Vitaliy І Bida, Alexander V Bida. (2019). Analysis of indicators of the orthopedic care provision to the adult population of Ukraine during 2012–2017. Wiad Lek, 72(5 cz 1), 914–917. PMID: 31175795.

V. P. Gavaleshko, M. V. Melnychuk, Ya. R. Karavan, M. O. Ishkov, V. I. Rozhko (2019). Modern view on prosthetic treatment of partial teeth loss (literature review). Clinical dentistry, (1): 40–47. [ В. П. Гавалешко, М. В. Мельничук, Я. Р. Караван, М. О. Ішков, В. І. Рожко. (2019). Сучасний погляд на ортопедичне лікування часткової адентії (огляд літератури). Клінічна стоматологія, (1), 40–47. ]. DOI: https://doi.org/10.11603/2311-9624.2019.1.10146.

Yanishen I. V., Diudina I. L. (2016). Pathogenetic mechanism of development of change in reception apparatus of teeth in during preparation hard tissues and impact the devitalization on fixedness to mechanical load (review of the literature). Bulletin of problems biology and medicine, 1(126): 62–66. [ Янішен І. В., Дюдіна І. Л. (2016). Патогенетичні механізми розвитку змін у рецепторному апараті зубів під час препарування твердих тканин та вплив депульпування на їх витривалість до механічних навантажень (огляд літератури). Вісник проблем біології і медицини, 1(126): 62–66. ]. URL: http://nbuv.gov.ua/UJRN/Vpbm_2016_1%281%29__13

Lau XE, Liu X, Chua H et al. (2023). Heat generated during dental treatments affecting intrapulpal temperature: a review. Clin Oral Investig, 27(5): 2277–2297. PMID: 37022531. DOI: https://doi.org/10.1007/s00784-023-04951-1.

Skibitskyi V. S. (2024). Temporary non-removable orthopedic structures are made using a CAD/CAM system by the milling method, as an alternative to permanent ones for a long time. Actual Dentistry, (4): 51. [ Скібіцький, В. С. (2024). Тимчасові незнімні ортопедичні конструкції виготовлені із використанням CAD/CAM системи методом фрезерування, як альтернатива постійним на тривалий термін. Cучасна стоматологія, (4): 51]. DOI: https://doi.org/10.33295/1992-576X-2024-4-51.

Zabuga Y. I., Germanchuk S. M., Bida O. V. (2013). Experimental justification of the use of surface protection agents for the preparation of hard tissues of vital teeth at the stages of orthopedic rehabilitation of patients. Ukrainian Dental Almanac, 1: 8 –11. [ Забуга Ю. І., Германчук С. М., Біда О. В. (2013). Eкспериментальне обґрунтування застосування засобів захисту поверхні препарування твердих тканин вітальних зубів на етапах ортопедичної реабілітації пацієнтів. Український стоматологічний альманах, 1: 8 –11]. URL: http://nbuv.gov.ua/UJRN/Usa_2013_1_4.

Kyrmanov, O. (2016). The results of comparative clinical evaluation of the use of plastic for temporary non-removable prosthesis. Ukrainian Dental Almanac, 1(3): 41–46. [ Кирманов О.С. (2016). Результати порівняльної клінічної оцінки застосування пластмас для тимчасового незнімного протезування. Український стоматологічний альманах, 3(1): 41–46. URL: https://dental-almanac.org/index.php/journal/article/view/174.

A Dawood, B Marti Marti, V Sauret-Jackson, A Darwood. (2015). 3D printing in dentistry. Br Dent J, 219(11): 521–529. PMID: 26657435. DOI: https://doi.org/10.1038/sj.bdj.2015.914.

Radi Masri, Carl F. Driscoll. (2023). Clinical applications of digital dental technology, 2nd Edition. Wiley-Blackwell, 400 p. ISBN: 978-1-119-80058-3.

Arthur R.G. Cortes. (2022). Digital Dentistry: A Step-by-Step Guide and Case Atlas. Wiley-Blackwell, 400 p. ISBN: 978-1-119-85199-8.

Published

2025-07-10

How to Cite

Skibitsky В., & Zakharova Г. (2025). Experience in Using Temporary Crowns Made According to a Digital Protocol for Prosthetics of Vital Teeth (Clinical Case). Actual Dentistry, (3), 110–116. https://doi.org/10.33295/1992-576X-2025-3-110

Issue

Section

ORTHOPEDIC DENTISTRY