The features of patient adaptation to removable partial dentures based on the dynamic study of the mucous membrane condition of an oral cavity in the new functioning conditions
DOI:
https://doi.org/10.33295/1992-576X-2022-3-33Keywords:
adaptation to removable dentures, thermoplastic polymer, acrylic polymer bases, polishing pastesAbstract
Relevance. Theadaptation to removable partial dentures is a multilevel process. At the beginning of usage, removable dentures irritate the tissues that interact directly with the prosthesis and are perceived as a foreign object by the patient. The irritating effect of prostheses is caused by their non-physiological pressure on the tissues that interact directly with the prosthesis, elimination of the bases plastic monomer, and change of the microbiological status of the oral cavity.
The goal of the study. To determine the features of clinical and functional adaptation of patients in orthopedic rehabilitation with thermoplastic and acrylic prostheses.
Materials and methods. For this clinical study, 60 patients with partial absence of teeth were examined. The patients underwent orthopedic rehabilitation with partial removable dentures (1st group — 30 patients used thermoplastic removable dentures; 2nd group — 30 patients used acrylic removable dentures).The number of patient visits for each of the studied groups for the correction in the adaptation period to fix partial removable dentures with bases of thermoplastic and acrylic materials treated with polishing pastes Blue Shine, ThermoGloss was analyzed.
Results. Clinical studies have shown clear advantages of thermoplastic prostheses. The obtained data indicate a much smaller negative impact on the removable denture bases made of thermoplastic polymer compared to the acrylic polymer bases. Also, thermoplastic dentures show better results in patient adaptation. Patients with removable dentures made of thermoplastic and acrylic polymers showed better clinical results if the surface of the dentures was treated with ThermoGloss polishing paste.
Conclusions. Using the ThermoGloss polishing paste for the final polishing of polymers has reduced the inflammatory response of the mucous membrane of the tissues that interact directly with the prosthesis and has increased its resistance to the negative effects of the partial removable dentures during adaptation. In turn, this helped reduce the number of visits to correct the prosthesis, as well as reduce the time of adaptation.
Downloads
References
Adler S., Kistler S., Kistler F., Lermer J., Neugerbauer J. Compression-moulding rather than milling: a wealth of possible applications for high performance polymers // Quintessenz Zahntechnik. - 2013; 39: 376-384.
Ayaz E.A., Durkan R., Koroglu А., Bagis B. Comparative effect of different polymerization techniques on residual monomer and hardness properties of PMMA-based denture resins // J. Appl. Biomater. Funct. Mater. 2014; 30: 228-233. PMID: 25199069, DOI: https://doi.org/10.5301/jabfm.5000199 PMid:25199069
Campbell S.D Cooper L., Craddock H., T. Paul Hyde, Brian Nattress, Sue H. Pavitt, David W. Seymour Removable partial dentures: the clinical need for innovation // J. Prosthet. Dent. - 2017; 118: 273-280. PMID: 28343666, doi: https://doi.org/10.1016/j.prosdent.2017.01.008 PMid:28343666
Fueki K., Ohkubo C., Yatabe M., Arakawa I., Arita M., Ino S. et all. Clinical application of removable partial dentures using thermoplastic resin. Part II: material properties and clinical features of non-metal claspdentures // J. Prosthodont. Res. - 2014; 58: 71-84. doi: https://doi.org/10.1016/j.jpor.2014.03.002 PMid:24746524
Makeyev V., Hunovskyi Ya.R, Skalskyi V., Hunovska R. Rezultaty vyvchennia osoblyvostei poverkhnevoi struktury stomatolohichnykh polimeriv dlia znimnoho protezuvannia metodom skanuiuchoi mikroskopii pislia yikh obrobky riznymy poliruvalnymy pastamy // Suchasna stomatolohiya. 2020; 1 (100): 7-11 [in Ukrainian].
Müller, F., Shimazaki, Y., Kahabuka, F., & Schimmel, M. (2017). Oral health for an ageing population: the importance of a natural dentition in older adults. In International Dental Journal (Vol. 67, pp. 7–13). Elsevier BV. https://doi.org/10.1111/idj.12329 PMid:29023743 PMCid:PMC9379181
Naito, M., Nakayama, T., & Fukuhara, S. (2004). In Health and Quality of Life Outcomes (Vol. 2, Issue 1, p. 31). Springer Science and Business Media LLC. https://doi.org/10.1186/1477-7525-2-31 PMid:15217517 PMCid:PMC449732
Nidzelsky, M., Chikor, V., & Tsvetkova, N. (2019). PHONETIC REHABILITATION FOR REMOVABLE DENTAL PROSTHETICS. In Ukrainian Dental Almanac (Issue 2, pp. 44–48). Ukrainian Medical Stomatological Academy. https://doi.org/10.31718/2409-0255.2.2019.09
Sadek, S. A., Dehis, W. M., & Hassan, H. (2018). Comparative Study Clarifying the Most Suitable Material to Be Used as Partial Denture Clasps. In Open Access Macedonian Journal of Medical Sciences (Vol. 6, Issue 6, pp. 1111–1119). Scientific Foundation Spiroski (publications). https://doi.org/10.3889/oamjms.2018.226 PMid:29983813 PMCid:PMC6026407
TAKABAYASHI, Y. (2010). Characteristics of denture thermoplastic resins for non-metal clasp dentures. In Dental Materials Journal (Vol. 29, Issue 4, pp. 353–361). Japanese Society for Dental Materials and Devices. https://doi.org/10.4012/dmj.2009-114 PMid:20644329
Downloads